Project

General

Profile

Actions

Bug #600

open

Internal short between LED+ and RST#

Added by Andrew Kohlsmith over 11 years ago. Updated over 11 years ago.

Status:
Feedback
Priority:
Normal
Start date:
03/18/2015
Due date:
% Done:

80%

Estimated time:

Description

I guess I didn't do the DRC with all layers on and ignored Eagle's "2 errors on hidden layers" warning.

The LED+ and RST# signals are shorted on layer 15 right at the LCD connector, and a via is too close to the LED+ trace on the same layer.


Files

picture8-1.png (73 KB) picture8-1.png Andrew Kohlsmith, 03/18/2015 05:01 PM
picture964-1.png (312 KB) picture964-1.png Andrew Kohlsmith, 03/18/2015 05:42 PM
picture964-2.png (448 KB) picture964-2.png Andrew Kohlsmith, 03/18/2015 05:42 PM
Actions

Also available in: Atom PDF